{"product_id":"ksb-calio-pro-25-60-nasslauferpumpe-1x230v-g-1-1-2-180-mm-pk25-241","title":"KSB Calio Pro 25-60 Wet Rotor Pump 1x230V G 1 1\/2\" 180 mm PK25\/241","description":"\u003ch1\u003e\u003cstrong\u003eHighly Efficient Wet Runner Pump KSB Calio Pro 25-60\u003c\/strong\u003e\u003c\/h1\u003e\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eArticle Number:\u003c\/strong\u003e 29135108\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e KSB\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eType:\u003c\/strong\u003e Calio Pro 25-60\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eDesign:\u003c\/strong\u003e Wet Runner Pump\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 5.4 kg\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eInstallation Length:\u003c\/strong\u003e 180 mm\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eConnection:\u003c\/strong\u003e RP 1, G 1 1\/2\"\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eRated Power (Pn): \u003c\/strong\u003e0.08 kW\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 0.125 A\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eSpeed: \u003c\/strong\u003e3700 rpm\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch2\u003e\n\n\u003cstrong\u003eKSB Calio Pro\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eHighly Efficient Heating Circulation Pump\u003c\/strong\u003e\n\n\u003c\/h2\u003e\u003cp\u003eMaintenance-free, highly efficient wet runner pump with a current-blocking synchronous motor based on ECM technology. Equipped with stepless differential pressure control for optimal system adaptation.\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eMain Applications\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eHeating, ventilation, air conditioning, and refrigeration systems\u003c\/li\u003e\n\n\u003cli\u003eCirculation systems\u003c\/li\u003e\n\n\u003cli\u003e1-pipe systems and 2-pipe systems\u003c\/li\u003e\n\n\u003cli\u003eSurface heating systems such as \u003cstrong\u003eunderfloor heating\u003c\/strong\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eBoiler circuits\u003c\/strong\u003e or \u003cstrong\u003eprimary circuits\u003c\/strong\u003e\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eOperating Modes\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eConstant pressure control\u003c\/li\u003e\n\n\u003cli\u003eProportional pressure control\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eDynamicControl Mode\u003c\/strong\u003e – dynamically adjusted differential pressure\u003c\/li\u003e\n\n\u003cli\u003eFixed speed operation with manually selectable speed\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eSetpoint input in \u003cstrong\u003emeters head\u003c\/strong\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003eOperating interface with symbols \u0026amp; plain text display for operating mode and setpoint\u003c\/li\u003e\n\n\u003cli\u003eError code display on the screen\u003c\/li\u003e\n\n\u003cli\u003eActivatable \u003cstrong\u003eventing function\u003c\/strong\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003eSoft start with \u003cstrong\u003einrush current limitation\u003c\/strong\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eDeblocking function\u003c\/strong\u003e for blocked shaft\u003c\/li\u003e\n\n\u003cli\u003eIntegrated motor protection\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eCommunication \u0026amp; Control\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eTerminal pair for \u003cstrong\u003etwin pump operation\u003c\/strong\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eCollective fault relay\u003c\/strong\u003e (potential-free changeover contact)\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eTechnical Data – Operating Range\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003ePumped Medium:\u003c\/strong\u003e Water (Concentration: 100 %)\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eMedium Temperature:\u003c\/strong\u003e 20 °C (permissible: -10 °C to +110 °C)\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eMax. Operating Pressure:\u003c\/strong\u003e 33.420 lbf\/ft²\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eMax. Ambient Temperature:\u003c\/strong\u003e 40 °C\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eMotor \u0026amp; Electronics\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eMains Connection:\u003c\/strong\u003e 1~230 V ±10 %, 50 Hz\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e IPX4D\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eElectromagnetic Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eEmission:\u003c\/strong\u003e EN 55014-1, EN 61000-3-2, EN 61000-3-3\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eImmunity:\u003c\/strong\u003e EN 55014-2\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eEmission Limit:\u003c\/strong\u003e ≤ 0.2\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eMaterials\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003ePump Casing:\u003c\/strong\u003e Grey cast iron, KTL-coated (EN-GJL-200)\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eShaft:\u003c\/strong\u003e Stainless steel 1.4034\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eImpeller:\u003c\/strong\u003e Plastic PSU-GF30 (with glass fiber content)\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eBearings:\u003c\/strong\u003e Ceramic\/Carbon\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eScope of Delivery\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003ePump incl. two-part thermal insulation shell according to EnEV\u003c\/li\u003e\n\n\u003cli\u003eKSB connection plug\u003c\/li\u003e\n\n\u003cli\u003eInstallation and operating instructions\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003cp\u003eFurther data can be found in the data sheet.\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eCondition:\u003c\/strong\u003e NEW (Original Packaging)\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eOur Article Number:\u003c\/strong\u003e PK25\/241\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"Pumpenkost","offers":[{"title":"Default Title","offer_id":57277157441876,"sku":"PK25\/241","price":608.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1078\/5620\/0020\/files\/ksb_calio_pro_1.jpg?v=1790297413","url":"https:\/\/www.pumpenkost.com\/en\/products\/ksb-calio-pro-25-60-nasslauferpumpe-1x230v-g-1-1-2-180-mm-pk25-241","provider":"Pumpenkost GmbH","version":"1.0","type":"link"}